ttamamusually replies in minutes11:21
pinnedfrom AED 150–600visit length 1–3 hourslocation Satwa, Dubaivendors verified
need wiring repair in satwa — today if possible11:21✓✓
tamam connects Satwa households and businesses with vetted electrician providers. You see the options, the AED range and the availability, then book directly.11:22
typical ranges vendors quote around satwa —Call-out with fault diagnosis (tripping breaker, dead circuit)AED 150–250Light fixture or ceiling fan installation, standard ceilingAED 150–350Chandelier installation with assembly, high ceilingAED 350–60011:23
that works. who actually turns up?11:24✓✓
licensed vendors only — the licence and vendor ID land in this chat before anyone rings your bell.11:25
Where a handyman stops and an approved contractor begins
Handyman-level work, which most tamam electrical bookings fall into, covers fault finding, socket and switch replacement, adding a socket as a spur on an existing circuit, light fixture and fan installation, water heater replacement on an existing point, and appliance connections. The technician should still be a trained electrician; handyman-level describes the regulatory weight of the job, not the skill it needs.
The boundary matters for more than compliance. Home insurance can walk away from a fire claim traced to unapproved modification of the fixed installation, and villa owners feel it at resale, when a buyer's inspection flags a DB full of undocumented additions. If a vendor quotes you for a load increase or a DB replacement without mentioning utility approval or an inspection step, that is your cue to ask harder questions or find another vendor.
Pricing in Satwa
Rather than publishing one rate, tamam shows what multiple verified vendors charge for wiring repair so you can pick the tier that fits the job and the budget.
Call-out with fault diagnosis (tripping breaker, dead circuit)AED 150–250
Light fixture or ceiling fan installation, standard ceilingAED 150–350
Chandelier installation with assembly, high ceilingAED 350–600
RCD or breaker replacement in the DBAED 200–450
Full tripping-fault trace and repair, flat or villa zoneAED 300–600
Nothing is charged until you have chosen a vendor and seen their number. There are no surprise call-out fees.
Frequently asked questions
Can a handyman add a new socket, or does that need DEWA approval?
A socket added as a spur from an existing nearby circuit is handyman-level work and needs no utility involvement, though in a rental you need landlord permission for anything cut into walls. A new circuit from the DB, a board upgrade or an increase in connected load crosses into approved-contractor territory with DEWA, SEWA, ADDC or Etihad WE, depending on your emirate.
My whole flat lost power but the neighbours are fine. Who do I call?
First check your own DB: if the main isolator or RCD has dropped, reset it once. If the board is fully on but the flat is dead, the fault is likely at the meter or the building's riser, which is the utility's or building management's side. Call the building's maintenance desk or the utility's fault line; a private electrician cannot legally open that part of the installation.
Do I have to pay for electrical repairs in my rented apartment?
Check your tenancy contract for a minor-maintenance clause; the common UAE arrangement makes tenants responsible for small repairs up to a stated amount per incident, with the landlord covering wear-and-tear and anything structural. An aging water heater leaking to earth is wear, not misuse, so document faults with photos and dates before agreeing to pay.
Are my 110V appliances from the US safe to use here?
Not directly. The UAE supply is 220–240V, and plugging a 110V appliance in without a step-down transformer will damage it, often immediately. Small dual-voltage electronics like laptop chargers are fine with a plug adapter, but motors, kitchen appliances and anything with a heating element need a correctly rated transformer or, more sensibly, a local replacement.
Can electricians work evenings or weekends in apartment towers?
Emergency fault attendance is generally allowed at any hour, but planned noisy work like drilling is restricted by most building managements to weekday daytime slots, commonly somewhere between 8am and 6pm. Quiet work such as fixture swaps or DB diagnosis is often fine in the evening. Confirm your building's rules before booking a time you cannot use.
Do you cover Satwa?
Satwa is within our Dubai coverage. Open the app to see which vendors have slots near you today.
Avoid these
Fixing nuisance trips by fitting a bigger breaker or a less sensitive RCD
Upsizing protection to stop tripping removes the safeguard while leaving the fault. An oversized MCB lets cables run hotter than they are rated for inside walls, and a desensitised RCD stops protecting people from a leaking water heater. Any vendor proposing this as the fix is the wrong vendor.
Buying the appliance or fixture before checking the ceiling or the board
The induction hob that needs a dedicated circuit your DB cannot spare, the chandelier your gypsum ceiling cannot carry, the dimmer your LED lamps do not support: all cheaper to discover before purchase. A short survey visit or even photos sent ahead prevents owning hardware you cannot install.
Treating outdoor electrics like indoor electrics
Indoor-grade junction boxes in flowerbeds, unrated extension cords feeding garden lights and balcony sockets without covers all fail the same way: moisture gets in, the RCD starts tripping, and the search for the wet joint costs more than proper IP-rated fittings would have. Outdoors, specification is the economy.