Low pressure on upper floors: your problem, or the building's
Weak showers on high floors are among the most misdiagnosed complaints in UAE plumbing. Towers move water in stages — transfer pumps to roof tanks, or pressurised booster sets, with pressure-reducing valves taming it back down per floor or per unit — and a failure anywhere in that chain shows up in your bathroom. The diagnostic split is simple and worth doing before you book anyone: if the whole floor or building is weak, it is the building's pump room and your route is a complaint to facilities management, not a plumber in your flat. If only your unit is affected, especially only the hot side, the suspects are a scaled heater inlet, a drifting apartment PRV, clogged cartridges or seized angle valves — all fixable in a normal visit, typically AED 150–400 depending on parts.
Villas play by different rules: they rely on their own pressure pump between tank and house, and when it fails or its vessel loses charge you get the classic symptom of pressure surging and dying rhythmically. Pump replacement is routine, but insist on a correctly sized unit rather than whatever is on the van — an oversized pump hammers the pipework and shortens the life of every flexible hose in the house, which is a slow-motion flood risk.