Al Rashidiya 2 sits in Ajman, and electrician here has its own rhythm: access rules, parking, and timing that a vendor who knows the area already understands.
Al Rashidiya 2 is primarily residential, so most bookings are villa or apartment work and timing follows family routines, which shapes how electrician jobs run here — vendors who cover the area already know the access routine, the parking situation and the timing that suits residents.
Vendor availability is steady and lead times are typically short. Typical on-site time is 1–3 hours. Vendors will flag it in advance if your job looks heavier than standard.
Tripping boards diagnosed, breakers and RCDs replaced.
Free to download, free to browse. You only pay when you book a job.
Get it on your phoneBook via WhatsAppThe honest answer on cost is a range, not a figure. For db board repair the typical band is AED 150–600, and you see each vendor's position in it before committing.
| what | guide price |
|---|---|
| Call-out with fault diagnosis (tripping breaker, dead circuit) | AED 150–250 |
| New socket point as a spur on an existing circuit | AED 180–350 |
| Chandelier installation with assembly, high ceiling | AED 350–600 |
Parts and consumables, where they apply, are quoted separately and approved by you first.
There is one safe DIY step: unplug everything on the affected circuit, reset the breaker, and reintroduce appliances one at a time. If the breaker holds until a specific device goes back in, you have found your culprit. If it snaps back instantly with nothing plugged in, or you notice a burning smell or a breaker that feels warm, stop resetting it and book a professional. Repeatedly forcing a breaker that wants to trip is how melted DB buswork happens.
UAE boards have a few local quirks worth knowing before trouble starts. Water heaters usually have their own switches, sometimes on the board and sometimes on the bathroom wall, and each split AC unit typically has a dedicated isolator. Older flats often carry a second small board for the heaters alone. Ten minutes spent flipping breakers one by one and writing what each controls on the board's door turns your next fault call from a vague description into a precise one, and shortens the electrician's paid diagnosis time accordingly.
The gap between tenancies is the only time you have an empty unit, full access and no one to inconvenience, which makes it the cheapest possible moment to deal with electrical wear. Faults found now cost a call-out; the same faults found by an unhappy tenant in month two cost a call-out plus an argument about liability, and unresolved snags are a recurring theme in deposit disputes at the rental committees.
A competent electrician can audit a one- or two-bedroom flat in a couple of hours: test every socket with a tester, press-test each RCD, check water heater elements for earth leakage before they become the next tenant's mystery trip, tighten DB terminals that loosen with thermal cycling, replace yellowed or cracked switch plates, and label the DB so the next occupant is not flipping breakers at random. In villas, add the garden circuits and the external water heater cupboards, which bake in the sun.
Humidity is the seasonal multiplier. From July to September, condensation forms inside outdoor sockets, balcony light fittings and external water heater cupboards, and boards that behaved all winter start tripping at 2am. A methodical electrician isolates circuits one by one at the DB, then uses an insulation resistance tester to find the leaking culprit, rather than swapping parts on instinct. Expect the diagnosis to take under an hour in a flat and longer in a villa with garden zones.
Two things not to do. Do not have the RCD replaced with a less sensitive one, or bypassed, to make the tripping stop; that removes the device that stops water heater faults from becoming electrocutions in the shower. And do not assume the RCD itself is broken just because the tripping seems random; genuinely faulty RCDs are the minority, though they do age, which is why the test button exists and is worth pressing every few months.
Not everything fits neatly into an app form. For anything custom in Al Rashidiya 2, whatsapp a coordinator and it gets handled manually.
You are booking a vetted business, not an anonymous number from a listings site: trade licence verified, insurance on file, technicians ID-tagged.
A breaker that keeps dropping is doing its job; the fault is still there. Repeated forced resets stress the breaker and, in worn boards, can overheat the buswork behind it. Reset once after unplugging the circuit's appliances; if it will not hold, stop and book a diagnosis.
Upsizing protection to stop tripping removes the safeguard while leaving the fault. An oversized MCB lets cables run hotter than they are rated for inside walls, and a desensitised RCD stops protecting people from a leaking water heater. Any vendor proposing this as the fix is the wrong vendor.
The induction hob that needs a dedicated circuit your DB cannot spare, the chandelier your gypsum ceiling cannot carry, the dimmer your LED lamps do not support: all cheaper to discover before purchase. A short survey visit or even photos sent ahead prevents owning hardware you cannot install.
First check your own DB: if the main isolator or RCD has dropped, reset it once. If the board is fully on but the flat is dead, the fault is likely at the meter or the building's riser, which is the utility's or building management's side. Call the building's maintenance desk or the utility's fault line; a private electrician cannot legally open that part of the installation.
Check your tenancy contract for a minor-maintenance clause; the common UAE arrangement makes tenants responsible for small repairs up to a stated amount per incident, with the landlord covering wear-and-tear and anything structural. An aging water heater leaking to earth is wear, not misuse, so document faults with photos and dates before agreeing to pay.
Not directly. The UAE supply is 220–240V, and plugging a 110V appliance in without a step-down transformer will damage it, often immediately. Small dual-voltage electronics like laptop chargers are fine with a plug adapter, but motors, kitchen appliances and anything with a heating element need a correctly rated transformer or, more sensibly, a local replacement.
Emergency fault attendance is generally allowed at any hour, but planned noisy work like drilling is restricted by most building managements to weekday daytime slots, commonly somewhere between 8am and 6pm. Quiet work such as fixture swaps or DB diagnosis is often fine in the evening. Confirm your building's rules before booking a time you cannot use.
Legitimate operators work under a licensed company rather than as anonymous freelancers, and for regulated work they should name their utility approval without being pressed. Booking through tamam adds a layer, since listed vendors are verified and the job, payment and history are recorded in the app, which also makes it easy to rebook the same technician who already knows your board.
Yes — Al Rashidiya 2 is covered across Ajman, with vendors who regularly work the area. Availability shows live in the app.