ttamamusually replies in minutes11:42
pinnedrange AED 150–700time needed 1–3 hoursserving Al Mamzar Sharjahbook via app or whatsapp
need ac installation in al mamzar sharjah — today if possible11:42✓✓
tamam connects Al Mamzar Sharjah households and businesses with vetted ac maintenance providers. You see the options, the AED range and the availability, then book directly.11:43
typical ranges vendors quote around al mamzar sharjah —Chemical coil wash (deep clean, per unit)AED 200–400Thermostat replacement, including standard partAED 150–350Condensate drain unblock and pan cleanAED 150–30011:44
that works. who actually turns up?11:45✓✓
licensed vendors only — the licence and vendor ID land in this chat before anyone rings your bell.11:46
Cost of ac installation
There is no single correct price for ac installation — there is a range, and where you land in it depends on scope and which vendor you pick. The app shows you that range up front.
Chemical coil wash (deep clean, per unit)AED 200–400
Thermostat replacement, including standard partAED 150–350
Condensate drain unblock and pan cleanAED 150–300
Capacitor or fan motor electrical repairAED 200–450
Duct cleaning, apartment or small villaAED 300–700
These bands reflect typical jobs. Unusual scope gets quoted individually, still before you commit.
why coils ice up in august
A frozen indoor coil looks like the unit is cooling too well. It is the opposite. The evaporator coil is designed to run cold but above 0°C, kept there by steady warm airflow across its fins. Restrict that airflow — a clogged filter, a dust-caked blower wheel — and the coil drops below freezing. Condensate that should drip into the pan freezes onto the fins, ice blocks more airflow, the coil gets colder still, and it snowballs until the unit blows a weak trickle of warmish air. Low refrigerant causes the same ice from the other direction: less gas means lower evaporator pressure and a colder coil. Two very different causes, two very different bills — a AED 150–300 clean, or a leak repair and regas — so a technician who quotes gas without checking the filter first is guessing at your expense.
August is peak icing season because the problems compound: humidity is at its annual maximum, filters carry three months of summer dust, and units run nearly 24 hours a day, so a marginal fault never gets a rest cycle to thaw. If you find ice, switch to fan-only mode for a few hours to melt it gently, put towels down, and do not chip at the fins — they are soft aluminium. Then book a proper diagnosis, because the ice returns within days if the cause is not found.
freon, R410A and R32: what a gas top-up actually means
Refrigerant is not fuel. It circulates in a sealed loop and is never consumed, so a unit that needs gas has a leak — full stop. The honest version of a regas visit: find the leak with a detector or nitrogen pressure test, repair it, pull a vacuum on the lines, then weigh in the exact charge printed on the nameplate. The dishonest version is a hose, a cylinder, and see-you-next-summer. If you have paid for top-ups two years running, you have paid twice for one unfixed leak.
The gas itself matters. Older UAE units run R22 — the gas everyone still calls freon — which is being phased out under the Montreal Protocol; imports are restricted and the shrinking supply gets pricier every year, so regassing an old R22 unit can cost a startling share of its remaining value. Most systems from the last decade use R410A, and newer machines increasingly use R32, more efficient but mildly flammable. The gases are not interchangeable: R410A runs at much higher pressures than R22, so you cannot refill an old system with new gas. When a technician says an ageing R22 unit with a leaking coil is not worth repairing, the arithmetic usually supports them.
the drip in the ceiling: condensate drains explained
In August humidity a hard-working unit pulls several litres of water a day out of your air. All of it lands in a shallow pan under the coil and leaves through a narrow drain pipe that runs nearly flat above your ceiling, stays damp all year, and is fed a steady diet of fine dust — perfect conditions for algae and sludge. When it blocks, the pan overflows quietly into the ceiling void, and the first sign is a spreading brown stain or a drip through a light fitting. In apartments there is a twist: the stain on your ceiling is very often the upstairs neighbour's FCU, because drain trays sit in the slab void between floors. Establish whose unit is leaking before paying for repairs.
The fix is undramatic: flush and vacuum the drain line, clean the pan, check the pipe's slope, and drop in a slow-dissolving anti-algae tablet. It is a standard line in a proper service, and at AED 150–300 as a standalone job it is cheap insurance against repainting a ceiling. If a unit has overflowed once, ask about fitting a float switch — a small sensor that shuts the unit down before the pan overflows again.
Frequently asked questions
How often should AC be serviced in the UAE?
Twice a year is the sensible minimum: a thorough pre-summer service in March or April, and a lighter check in autumn. Villas with multiple ducted units, homes near construction, and anywhere on the coast benefit from quarterly attention. Filters are separate — wash those yourself monthly through summer.
Why does my AC freeze up in summer?
Ice on the indoor coil means the coil dropped below freezing, which has two usual causes: restricted airflow from a clogged filter or dirty blower, or low refrigerant from a leak. Switch to fan-only mode to thaw it and book a diagnosis — the ice returns within days if the cause is not fixed.
My flat is on district cooling — what can a technician actually fix?
Everything on your side of the wall: the fan coil unit's blower, the actuator valve, the thermostat, filters, coil cleanliness and the drain pan. The temperature of the chilled water arriving from Empower, Tabreed or the building plant is outside their control, so if the FCU checks out and cooling is still weak, the next call is to facilities management.
Can I install a smart thermostat on my UAE fan coil unit?
Only with the right model. Many imported smart stats are built for 24-volt systems, while UAE FCUs typically switch 220 volts directly, and fitting the wrong one is a safety hazard. Proper 220V FCU-compatible smart thermostats exist — specify that requirement and treat installation as electrical work.
What is the difference between coil cleaning and duct cleaning?
Coil cleaning treats the wet machinery — evaporator coil, blower wheel and drain pan — with chemical foam, and fixes most smells and airflow loss; it is worth doing annually. Duct cleaning treats the air tunnels with agitation brushes and negative-pressure vacuum, and is a deeper, less frequent job, sensible every two to three years or after renovation.
Do you cover Al Mamzar Sharjah?
We cover Al Mamzar Sharjah and the surrounding Sharjah communities. Message on whatsapp if you want a specific time confirmed first.